Energy Analysis of Steam Cycle Efficiency with Feed Water Heater Modification (Case Study: PT. Pertamina EP Asset 1 Field Lirik)

  • Romy Romy Mechanical Engineering, Universitas Riau, Indonesia
  • Muhammad Rizki Mechanical Engineering, Universitas Riau, Indonesia

Abstract

The increasing energy efficiency program will decrease the consumption of energy. If these improvements are carried out together, it will certainly ensure energy reliability for a sustainable and better future. The aim of this paper was to investigate the possibility of increasing efficiency in the crude oil heating system at PT. Pertamina EP Asset 1 Lirik Field. The research method was done by modification the steam cycle using the close and open Feed Water Heater (FWH). As result, the efficiency of steam cycle of close FWH increased 2.53% and 2.78% for open FWH. While the efficiency of the steam cycle in the initial conditions was 36.74%.

Published
Nov 30, 2021
How to Cite
ROMY, Romy; RIZKI, Muhammad. Energy Analysis of Steam Cycle Efficiency with Feed Water Heater Modification (Case Study: PT. Pertamina EP Asset 1 Field Lirik). Journal of Ocean, Mechanical and Aerospace -science and engineering-, [S.l.], v. 65, n. 3, p. 88-93, nov. 2021. ISSN 2527-6085. Available at: <https://isomase.org/Journals/index.php/jomase/article/view/253>. Date accessed: 28 dec. 2025. doi: http://dx.doi.org/10.36842/jomase.v65i3.253.
Abstract viewed = 0 times
pdf downloaded = 0 times